Indoor Evaporator Temperature Sensor Open or Short Circuit
What it means
This code appears on Gree split air conditioners when the control board reads an impossible value from the indoor evaporator (coil) temperature sensor, meaning the sensor or its circuit is open or shorted. The unit relies on this sensor for evaporator anti-freeze protection and for indoor fan control in heat mode, so it stops or limits operation when the code appears. The same code can mean something else on other brands.
Models covered: Gree split (wall-mounted) air conditioners, mainly inverter models; the code shows on the indoor unit display. Older non-inverter models may show fewer codes.
Symptoms3
- The compressor stops and there is no cooling while the indoor fan may run.
- The code sometimes appears right after the indoor unit was washed.
- In some cases ice forms on the evaporator before the code shows.
Possible causes5
- Loose or corroded sensor connector on the indoor control board, which is the most common cause.
- Failed sensor (thermistor) from moisture or age.
- Broken or chafed sensor wire from rubbing, rodents or heat.
- Sensor pulled out of its pocket on the evaporator pipe after a service or wash.
- Faulty sensor input circuit on the indoor control board, which is less common.
How to diagnose5
- Switch off at the breaker for a few minutes and restart to see if the code is permanent.
- The technician checks the sensor connector on the indoor control board and reseats it firmly.
- The technician removes the sensor, measures its resistance and compares it with the Gree resistance table at a known temperature.
- The technician inspects the wire along its length for breaks or chafing.
- If the sensor and wire are fine, the technician tests the board with a known-good sensor.
How to fix5
- Clean and firmly reseat the connector.
- Repair and insulate the damaged wire.
- Replace the sensor with the correct part for the model and fit it in its original position.
- Replace the indoor control board only if its input circuit is proven faulty.
- Run the unit and confirm the code is gone and cooling is normal.
Repair cost
In Saudi riyals; the highlighted part is the expected range for this fault.
A connector clean or a new sensor is usually enough and cheap; the cost only rises if the control board has to be replaced.
Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026
Frequently asked questions
Is F2 linked to E2?
Yes. E2 anti-freeze protection relies on this sensor, so a sensor reading wrong can trigger E2 without a real freezing problem.
Why did F2 appear after an AC wash?
Water may have entered the connector or the sensor slipped out of its pipe pocket. Let the unit dry and have the technician refit it.
Was this explanation helpful?
Tap the stars to rate; you can change it later.
What was wrong? (optional)
This guide is for information only and does not replace an inspection by a qualified technician. If the fault involves brakes, steering, engine temperature, electrics or refrigerant, do not attempt the repair yourself.