E2

Indoor Evaporator Anti-Freeze Protection

Home Appliance Error Codes Gree Split AC

Severity Medium Do not ignore it; it may get worse and cost more.
Can you still use it? With care until repaired
Who can fix it? DIY with some experience
Typical repair time 30 minutes – 3 hours
Typical cost SAR 80 to 1,100

What it means

This code appears on Gree split air conditioners when the indoor evaporator temperature drops close to freezing during cooling or dry mode. The unit stops the compressor temporarily while the indoor fan keeps running until the coil warms up, then resumes on its own. The same code can mean something else on other brands.

Models covered: Gree split (wall-mounted) air conditioners, mainly inverter models; the code shows on the indoor unit display. Older non-inverter models may show fewer codes.

Symptoms4

  • Ice or frost visible on the evaporator fins or on the small pipe at the outdoor unit.
  • Weak airflow from the indoor unit.
  • Water dripping from the indoor unit after the ice melts.
  • Cooling stops for periods, then resumes.

Possible causes6

  • Dirty or blocked indoor filters reducing airflow across the evaporator, which is the most common cause.
  • Dirty evaporator fins or indoor blower wheel.
  • Low refrigerant from a leak, lowering evaporator pressure and temperature.
  • Low indoor fan speed from a motor or board fault.
  • Running on the lowest temperature and lowest fan speed for long periods in an already cool room.
  • Faulty evaporator temperature sensor reading colder than actual.

How to diagnose5

  1. Switch off the power, remove and wash the filters, let them dry, then restart.
  2. If the coil is iced, run fan-only mode until it has fully melted before cooling again.
  3. Confirm the indoor fan changes speed when you change it on the remote.
  4. The technician checks operating pressure and looks for a leak if it is low.
  5. The technician measures the evaporator sensor resistance and compares it with the manufacturer table at a known temperature.

How to fix5

  1. Clean the filters every two weeks in the dusty season.
  2. Wash the evaporator and indoor blower during a full service.
  3. Raise the set temperature and avoid the lowest fan speed combined with the lowest setting.
  4. Have a licensed technician repair the leak and recharge if the charge is low.
  5. Replace the evaporator sensor or fan motor as tested, then run the unit for an hour and confirm the code does not return.

Repair cost

In Saudi riyals; the highlighted part is the expected range for this fault.

Most cases are solved by cleaning filters or servicing the indoor unit; the cost rises when a leak needs brazing and a recharge.

Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026

Frequently asked questions

Is E2 a real fault or just protection?

It is protection that stops the coil freezing and liquid reaching the compressor, but repeated E2 points to a cause such as dirty filters or low refrigerant.

Is it harmful to run the AC with ice on the coil?

Yes. Ice blocks airflow and loads the compressor. Melt it with fan mode first, then find the cause.

Was this explanation helpful?