Outdoor Discharge Temperature Sensor Open or Short Circuit
What it means
This code appears on Gree split air conditioners when the control board reads an impossible value from the compressor discharge temperature sensor, meaning the sensor or its circuit is open or shorted. Without this sensor the unit cannot protect the compressor from overheating, so it stops the outdoor unit until it is repaired. The same code can mean something else on other brands.
Models covered: Gree split (wall-mounted) air conditioners, mainly inverter models; the code shows on the indoor unit display. Older non-inverter models may show fewer codes.
Symptoms3
- The outdoor unit stops and there is no cooling.
- The code appears shortly after start-up.
- It may appear after work inside the outdoor unit.
Possible causes5
- Loose or corroded sensor connector on the outdoor control board, which is the most common cause.
- Failed sensor (thermistor) from moisture or age.
- Broken or chafed sensor wire from rubbing, rodents or heat.
- Wire insulation burnt or damaged from touching the hot discharge pipe.
- Faulty sensor input circuit on the outdoor control board, which is less common.
How to diagnose5
- Switch off at the breaker for a few minutes and restart to see if the code is permanent.
- The technician checks the sensor connector on the outdoor control board and reseats it firmly.
- The technician removes the sensor, measures its resistance and compares it with the Gree resistance table at a known temperature.
- The technician inspects the wire along its length for breaks or chafing.
- If the sensor and wire are fine, the technician tests the board with a known-good sensor.
How to fix5
- Clean and firmly reseat the connector.
- Repair and insulate the damaged wire.
- Replace the sensor with the correct part for the model and fit it in its original position.
- Replace the outdoor control board only if its input circuit is proven faulty.
- Run the unit and confirm the code is gone and cooling is normal.
Repair cost
In Saudi riyals; the highlighted part is the expected range for this fault.
A connector clean or a new sensor is usually enough and cheap; the cost only rises if the control board has to be replaced.
Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026
Frequently asked questions
Can I run the AC with F5?
Not recommended. The unit stops the compressor because it cannot monitor its temperature, and bypassing that risks compressor damage.
Why does this sensor wire fail more than others?
It sits on the hottest pipe in the circuit, so if the lead touches the pipe or compressor body its insulation burns over time.
This guide is for information only and does not replace an inspection by a qualified technician. If the fault involves brakes, steering, engine temperature, electrics or refrigerant, do not attempt the repair yourself.
Report a mistake
Spotted something inaccurate? Tell us and we will review and correct it.
Report received — thank you
This is your private tracking link. It shows the status and our reply as soon as it is posted.