Indoor Evaporator Inlet Temperature Sensor Error
What it means
This code appears on Samsung inverter split wall units such as WindFree and Digital Inverter. It means the thermistor on the evaporator inlet pipe is open or shorted. The unit needs this sensor to watch coil temperature and prevent freezing, so it normally stops the compressor. The same code can mean something else on other brands.
Models covered: Samsung inverter split air conditioners (e.g. WindFree and Digital Inverter wall units) that show three-digit E codes on the display.
Symptoms3
- E122 shows and cooling stops.
- The indoor fan runs but the air is not cold.
- The code comes back after every restart.
Possible causes5
- Sensor out of its holder on the evaporator pipe, or its plug is loose.
- Sensor damaged by constant moisture on the cold coil.
- Wire cut or corroded where it runs beside the coil.
- Corrosion or water on the connector.
- Faulty sensor input on the indoor PCB.
How to diagnose5
- Switch off the breaker for a few minutes, then restart.
- A technician checks the sensor sits in its holder on the evaporator pipe and the wire is intact.
- Measure the sensor resistance against the Samsung table.
- Inspect the plug and socket for corrosion or moisture.
- If the sensor is good, check the sensor input on the indoor board.
How to fix5
- Refit the sensor and clean and dry the connector.
- Repair the damaged wire.
- Replace the evaporator inlet sensor (it may come as an indoor sensor set).
- Replace the indoor PCB if the sensor is proven good.
- Run the unit and confirm cooling without the code returning.
Repair cost
In Saudi riyals; the highlighted part is the expected range for this fault.
The usual fix is a low-cost sensor or sensor set; the top of the range covers the indoor PCB.
Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026
Frequently asked questions
Does E122 mean low refrigerant?
No. The code concerns the sensor or its wiring. Low refrigerant or a leak is shown by Samsung with a different code, such as E554.
Can a faulty sensor cause the coil to freeze?
The unit stops the compressor when the code shows to avoid that, but a sensor that misreads without setting a code can cause freezing or unsteady cooling.
Was this explanation helpful?
Tap the stars to rate; you can change it later.
What was wrong? (optional)
This guide is for information only and does not replace an inspection by a qualified technician. If the fault involves brakes, steering, engine temperature, electrics or refrigerant, do not attempt the repair yourself.