F4

Outdoor EEPROM Error

Home Appliance Error Codes Midea Split AC

Severity Medium Do not ignore it; it may get worse and cost more.
Can you still use it? No, unplug it
Who can fix it? Needs an authorized technician
Typical repair time 30 minutes – 3 hours
Typical cost SAR 100 to 2,500

What it means

This code appears on Midea split air conditioners with the classic code set when the outdoor board cannot read operating data from its EEPROM memory chip, so the outdoor unit will not run. The meaning may differ on some Midea series, so check the unit manual; it can also mean something else on other brands.

Models covered: Midea residential split air conditioners with the classic display codes (E0–EC, F1–F4, P0–P4); newer Midea series use different codes (EH, EL, PC) and some models differ.

Symptoms3

  • The outdoor unit does not run while the indoor fan runs with no cooling.
  • The code sometimes appears after a power cut or fluctuation.
  • Changing settings on the remote does not clear it.

Possible causes4

  • Temporary memory fault after a power cut or voltage surge.
  • Failed memory chip on the outdoor board.
  • Moisture or conductive dust on the outdoor board.
  • General outdoor board failure.

How to diagnose4

  1. Switch off at the breaker for several minutes, then restart.
  2. Check the supply is stable, especially if the code follows power cuts.
  3. After confirming the board is discharged, the technician inspects the outdoor board for moisture or burning.
  4. If the code stays, the technician replaces the outdoor board with one matched to the model number.

How to fix4

  1. Restart after a few minutes with the power off.
  2. Clean and dry the outdoor board and close the electrical box cover properly.
  3. Replace the outdoor board with a matching part at a service center.
  4. Fit a voltage protector to prevent repeats, then confirm the outdoor unit runs without the code.

Repair cost

In Saudi riyals; the highlighted part is the expected range for this fault.

A power reset may solve it; otherwise the outdoor inverter board is the main cost.

Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026

Frequently asked questions

What is the difference between E0 and F4?

E0 concerns the indoor board memory, while F4 concerns the outdoor board memory, so the place to check and the replacement part differ.

Do I need a genuine board?

It must match the model number and capacity, because the memory data sets how the compressor is driven.

Was this explanation helpful?

Tap the stars to rate; you can change it later.

This guide is for information only and does not replace an inspection by a qualified technician. If the fault involves brakes, steering, engine temperature, electrics or refrigerant, do not attempt the repair yourself.

Report a mistake