F1

Outdoor Ambient Temperature Sensor Open or Short Circuit

Home Appliance Error Codes Midea Split AC

Severity Medium Do not ignore it; it may get worse and cost more.
Can you still use it? No, unplug it
Who can fix it? Needs a technician
Typical repair time 30 minutes – 2 hours
Typical cost SAR 80 to 2,500

What it means

This code appears on Midea split air conditioners with the classic code set when the outdoor ambient temperature sensor (T4) reading is impossible, meaning an open or short circuit. The outdoor unit uses this reading to set compressor and fan speed and operating limits, so it stops or runs restricted. The sensor code order differs on some Midea series, so match the code with the unit manual. The same code can mean something else on other brands.

Models covered: Midea residential split air conditioners with the classic display codes (E0–EC, F1–F4, P0–P4); newer Midea series use different codes (EH, EL, PC) and some models differ.

Symptoms3

  • Weak cooling or the outdoor unit stops.
  • The code shows on the indoor unit although the sensor is outside.
  • The outdoor fan may run at an unusual speed.

Possible causes5

  • Loose or corroded sensor connector on the outdoor board.
  • Failed sensor (thermistor).
  • Cut, chafed or rodent-damaged sensor wire.
  • Sensor or wire damage from sun, extreme heat and dust.
  • Faulty sensor input circuit on the outdoor board, the least likely cause.

How to diagnose5

  1. Switch off at the breaker for a few minutes and restart to see if the code is permanent.
  2. With the power off, the technician opens the outdoor board cover and checks the T4 sensor connector.
  3. The technician measures the T4 sensor resistance and compares it with the Midea table for the same temperature.
  4. The technician traces the wire for breaks or chafing.
  5. If the sensor and wire are fine, the technician tries a known-good sensor before blaming the board.

How to fix5

  1. Clean the connector and seat it firmly.
  2. Repair or replace the wire.
  3. Fit a new matching T4 sensor in its original position.
  4. Replace the outdoor board if its input circuit is proven faulty.
  5. Run the unit and confirm the code is gone.

Repair cost

In Saudi riyals; the highlighted part is the expected range for this fault.

Most cases are a sensor or connector at low cost; the outdoor board is what raises the cost if it has failed.

Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026

Frequently asked questions

Why is the sensor outside but the code inside?

The outdoor board reports its sensors to the indoor board, which shows the code, so testing is done at the outdoor unit.

Can F1 mean something else on another Midea unit?

Yes. The outdoor sensor code order differs on some series, so match the code with your unit manual before buying any part.

Was this explanation helpful?

Tap the stars to rate; you can change it later.

This guide is for information only and does not replace an inspection by a qualified technician. If the fault involves brakes, steering, engine temperature, electrics or refrigerant, do not attempt the repair yourself.

Report a mistake

Spotted something inaccurate? Tell us and we will review and correct it.

Only if you want an email when we reply.

7 + 2 = ?

Related codes