CH44

Outdoor Air Temperature Sensor Error

Home Appliance Error Codes LG Split AC

Severity Medium Do not ignore it; it may get worse and cost more.
Can you still use it? With care until repaired
Who can fix it? Needs a technician
Typical repair time 30 minutes – 3 hours
Typical cost SAR 80 to 2,500

What it means

This code appears on LG inverter split air conditioners and on LG ducted and cassette units that use CH codes. It means the outdoor air thermistor on the outdoor unit is giving an impossible reading because of an open or short circuit. The unit uses this reading to set compressor and outdoor fan speed, so depending on the model it stops the compressor or runs in a limited protective mode. The same code can mean something else on other brands.

Models covered: LG inverter split air conditioners (e.g. Dual Inverter) and LG ducted/cassette units that use CH codes; the code shows as CH plus a number on the display or as LED blinks.

Symptoms3

  • CH44 shows on the display or as the matching blink pattern.
  • Cooling stops or becomes clearly weaker.
  • The code may appear after washing the outdoor unit or after rain.

Possible causes5

  • Sensor slipped out of its holder on the condenser grille, or damaged by sun and dust.
  • Water got into the sensor or its connector during a high-pressure wash.
  • Cut or corroded sensor wire.
  • Loose or corroded connector on the outdoor PCB.
  • Faulty sensor input on the outdoor PCB.

How to diagnose5

  1. Switch off the breaker for a few minutes and restart; if the code appeared after washing, let the unit dry and try again.
  2. A technician checks the sensor in its holder behind the condenser and its wire up to the board.
  3. Measure the sensor resistance against the LG table at the current air temperature.
  4. Inspect the connector and socket for water or corrosion.
  5. If the sensor is good, check the sensor input on the outdoor PCB.

How to fix5

  1. Dry and clean the connector and refit the sensor in its holder.
  2. Repair and insulate a cut wire.
  3. Replace the outdoor air sensor with the correct part.
  4. Replace the outdoor PCB if its sensor input is faulty.
  5. Run the unit and confirm normal cooling without the code.

Repair cost

In Saudi riyals; the highlighted part is the expected range for this fault.

The usual fix is a simple sensor or drying the connector at low cost; the top of the range, an outdoor PCB, is rare.

Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026

Frequently asked questions

CH44 appeared after washing the outdoor unit. What now?

Water probably reached the sensor or its connector. Switch off, let the unit dry for several hours and restart; if the code stays, the sensor needs testing.

Does summer heat affect this sensor?

It is designed for outdoor temperatures, but years of direct sun and dust can damage its casing and wire, and then the fault appears.

Was this explanation helpful?

Tap the stars to rate; you can change it later.

This guide is for information only and does not replace an inspection by a qualified technician. If the fault involves brakes, steering, engine temperature, electrics or refrigerant, do not attempt the repair yourself.

Report a mistake

Spotted something inaccurate? Tell us and we will review and correct it.