Indoor Fan Motor Lock or Overload
What it means
This code appears on Daikin split, ducted and cassette air conditioners and means the board did not receive a proper rotation signal from the indoor fan motor, or the motor is drawing too much current because it is stuck or dragging. The unit stops to protect the motor and the board, and the same code can mean something else on other brands.
Models covered: Daikin split air conditioners and Daikin ducted/cassette (SkyAir) units, which share the same error code system; the code shows on the wired remote or via the wireless remote check function.
Symptoms4
- The indoor fan does not turn, or turns slowly and then stops.
- The unit stops a few minutes after starting and A6 appears.
- Rubbing or clicking noise from inside the indoor unit.
- A faint burning smell in some cases.
Possible causes5
- A foreign object or heavy dirt stopping the blower wheel or fan blades.
- Worn fan motor bearings making the motor stiff or seized.
- A loose or corroded fan motor connector on the board.
- A failed fan motor or internal motor circuit.
- A faulty fan drive circuit on the indoor PCB.
How to diagnose5
- Switch the unit off at the breaker before touching it.
- With the power off, turn the fan gently by hand: it should spin freely without rubbing.
- Look for foreign objects or heavy dirt on the fan blades.
- A technician checks the motor connector and wiring and tests the motor and its rotation signal per the Daikin service manual.
- If the motor is good but the signal does not arrive, the board is the likely fault.
How to fix5
- Remove any foreign objects and clean the fan and indoor unit.
- Reseat the motor connector or repair the damaged wire.
- Replace the indoor fan motor if it is seized or faulty.
- Replace the indoor PCB if its fan circuit is proven faulty.
- Run the unit and confirm the fan works at all speeds and the code does not return.
Repair cost
In Saudi riyals; the highlighted part is the expected range for this fault.
Cleaning the fan or fixing a connector is cheap; the cost rises with a new fan motor and is highest when the board turns out to be the cause.
Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026
Frequently asked questions
Can dirt alone cause A6?
Yes. Dust and grease on the blower wheel add weight and unbalance it, and cleaning it may be enough. Always switch off the power first.
Why does the unit stop instead of running with a weak fan?
Running the compressor without enough air over the evaporator freezes it, and a stuck motor can overheat and damage the board, so the system shuts down to protect itself.
This guide is for information only and does not replace an inspection by a qualified technician. If the fault involves brakes, steering, engine temperature, electrics or refrigerant, do not attempt the repair yourself.
Report a mistake
Spotted something inaccurate? Tell us and we will review and correct it.
Report received — thank you
This is your private tracking link. It shows the status and our reply as soon as it is posted.
The link is saved in this browser only.