84

Current Sensor Error

Home Appliance Error Codes Fujitsu Split AC

Severity High Get it checked soon and avoid long use.
Can you still use it? No, unplug it
Who can fix it? Needs an authorized technician
Typical repair time 1 hour – 3 hours
Typical cost SAR 150 to 2,500

What it means

This code appears on Fujitsu General split and ducted units on the wired remote or indoor display; older models show it as a number of indicator lamp blinks instead of a number. It means the current sensor on the outdoor board, which measures the current drawn by the compressor, gives an impossible reading or none at all. Without this reading the unit cannot protect the compressor from overcurrent, so it stops it. The same number can mean something different on other brands.

Models covered: Fujitsu General (Fujitsu, O General) split and ducted units that show a two-digit error code on the wired remote or indoor display; older models show errors as lamp blink counts instead.

Symptoms4

  • The outdoor unit runs briefly, then stops, with no cooling.
  • The code or a set blink pattern appears after the compressor starts.
  • The code returns after every restart.
  • The compressor may not run at all although the outdoor unit has power.

Possible causes5

  • A faulty current sensor or its circuit on the outdoor board.
  • Loose or burnt board connectors or compressor wires.
  • A compressor that is not running and so draws no current, making the reading look wrong.
  • Very low refrigerant lowering the compressor load and current.
  • Board damage from a voltage surge.

How to diagnose5

  1. Switch off at the breaker for a few minutes and restart once.
  2. Do not open the outdoor unit yourself; its board holds a dangerous charge after switch-off.
  3. The technician confirms whether the compressor really starts and measures its current against the service manual values.
  4. After discharging the board, the technician checks board connectors and compressor wires.
  5. The technician checks refrigerant pressure to rule out low charge before blaming the board.

How to fix5

  1. Restart after a power-off; a one-off glitch may clear.
  2. Tighten connectors and repair burnt wiring.
  3. Repair the leak and recharge refrigerant by a licensed technician if the charge is low.
  4. Fit a voltage protector if the supply is unstable.
  5. Replace the outdoor board at an authorized service center if the sensing circuit is faulty, then confirm the code does not return.

Repair cost

In Saudi riyals; the highlighted part is the expected range for this fault.

The cost is low for a connector or wire, moderate for a refrigerant leak repair, and reaches the top of the range when the outdoor board is replaced.

Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026

Frequently asked questions

Is the code always a board fault?

No. If the compressor does not start or refrigerant is low, the current reading looks wrong. These are checked before the board is replaced.

Can I run the unit with this code?

No. The unit cannot protect the compressor from overcurrent, so it stops it. Wait for the technician.

Was this explanation helpful?

Tap the stars to rate; you can change it later.

This guide is for information only and does not replace an inspection by a qualified technician. If the fault involves brakes, steering, engine temperature, electrics or refrigerant, do not attempt the repair yourself.

Report a mistake

Spotted something inaccurate? Tell us and we will review and correct it.

Only if you want an email when we reply.