Outdoor Fan Motor Stopped
What it means
This code appears on the wired remote of Mitsubishi Electric Mr. Slim ducted, ceiling and cassette units. It means the outdoor board did not detect the outdoor fan turning, or detected an abnormal speed, while running. The unit stops the compressor because running it without the fan quickly drives pressure and temperature up. The same code can mean something else on other brands, and wall-mounted Mitsubishi Electric models show errors as lamp blinks with a different meaning.
Models covered: Mitsubishi Electric ducted, ceiling and cassette units (Mr. Slim) with check codes on the wired remote; wall-mounted Mitsubishi Electric models may show errors as lamp blinks with a different meaning.
Symptoms4
- The outdoor fan is stopped or slow and the compressor shuts off.
- U8 appears a few minutes after start.
- Rubbing noise or vibration from the fan before it stops.
- The outdoor unit runs hot and cooling weakens before the code.
Possible causes5
- Something blocking the blades, such as bags, branches or bird nests.
- A failed outdoor fan motor or worn bearings from heat and dust.
- A loose motor connector or damaged lead.
- A fault in the motor drive circuit on the outdoor board.
- A broken blade or a blade loose on the motor shaft.
How to diagnose5
- Turn the unit off at the breaker before going near the fan.
- Look through the grille for obstructions, and with power fully off check that the blade turns freely when nudged with a stick.
- Switch off at the breaker before opening any panel; the outdoor unit and its inverter board keep a dangerous charge for a while after switch-off.
- The technician checks the motor connector, lead, bearings and blade.
- The technician tests the motor and the board output using the manufacturer method to decide whether the motor or the board is at fault.
How to fix6
- Remove the obstruction and clean the outdoor unit.
- Reseat the motor connector or repair the lead.
- Secure or replace a damaged fan blade.
- Replace the outdoor fan motor.
- Replace the outdoor control board if it does not drive the motor.
- Run the unit and confirm steady fan speed and no code.
Repair cost
In Saudi riyals; the highlighted part is the expected range for this fault.
The cost is low for an obstruction or connector, rises for a new fan motor, and is highest if the outdoor unit needs a new board.
Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026
Frequently asked questions
Can I run the unit with the outdoor fan stopped?
No. Running the compressor without condenser airflow drives pressure and temperature up fast and can damage it, so leave the unit off until the fan is fixed.
Does the outdoor fan motor need a capacitor?
Many inverter units use board-driven motors without a capacitor, so the technician tests the motor and the board output together.
Is U8 more common after dust storms?
It can be, if dust and debris build up around the motor or objects get between the blades, which is why routine outdoor unit service helps.
Was this explanation helpful?
Tap the stars to rate; you can change it later.
What was wrong? (optional)
This guide is for information only and does not replace an inspection by a qualified technician. If the fault involves brakes, steering, engine temperature, electrics or refrigerant, do not attempt the repair yourself.
Report a mistake
Spotted something inaccurate? Tell us and we will review and correct it.
Report received — thank you
This is your private tracking link. It shows the status and our reply as soon as it is posted.
The link is saved in this browser only.