Indoor High Pressure Protection
What it means
This code appears on Panasonic inverter split air conditioners and is read from the fault history with the CHECK button. It means the indoor coil sensor saw a very high coil temperature during heating, a sign of high pressure, so the unit reduced or briefly stopped the compressor for protection. It is a protection code and the unit usually resumes on its own; the same number can mean something else on other brands.
Models covered: Panasonic residential inverter split air conditioners (wall mounted); the code is read with the CHECK button on the remote control.
Symptoms4
- Heating stops for a while and then restarts by itself.
- Weak airflow from the indoor unit in heating.
- Sometimes no clear symptom, and the code is found only in the fault history.
- Stops repeat when heating runs on a low fan speed.
Possible causes6
- Dust-clogged indoor filters reducing airflow over the coil.
- A dirty indoor coil or cross-flow fan.
- Fan speed set to the lowest step with a high set temperature.
- A weak or faulty indoor fan motor.
- A wrong reading from the indoor coil sensor.
- Refrigerant overcharged after an incorrect recharge (less common).
How to diagnose5
- Switch off the power, remove the filters, wash them and let them dry before refitting.
- Make sure the air inlet and outlet are not covered by curtains or furniture.
- Run heating with auto or high fan speed and see whether the stops repeat.
- The technician checks the coil and fan for dirt and measures the fan motor speed.
- The technician compares the coil sensor resistance with the manufacturer table and checks the refrigerant charge if the fault remains.
How to fix5
- Clean the filters regularly, every two weeks in dusty seasons.
- Have the indoor coil and cross-flow fan fully cleaned.
- Use auto or a higher fan speed when heating.
- Replace the coil sensor or fan motor if proven faulty.
- Have a licensed technician correct an overcharge, then confirm the code does not return.
Repair cost
In Saudi riyals; the highlighted part is the expected range for this fault.
Usually nothing more than filter cleaning or an indoor service is needed; the cost rises if the fan motor or board has to be replaced.
Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026
Frequently asked questions
Is H98 a real fault?
It is a protection code, not necessarily a failed part. If it appears once in the history and the unit works normally, clean the filters and watch it; call a technician if it repeats.
I only use cooling, so why is H98 stored?
This protection is linked to heating, so the code may be stored from earlier heating use. Ask the technician to clear the history and watch whether it returns.
Was this explanation helpful?
Tap the stars to rate; you can change it later.
What was wrong? (optional)
This guide is for information only and does not replace an inspection by a qualified technician. If the fault involves brakes, steering, engine temperature, electrics or refrigerant, do not attempt the repair yourself.
Report a mistake