Indoor Fan Motor Error
What it means
This code appears on Fujitsu General split and ducted units on the wired remote or indoor display; older models show it as a number of indicator lamp blinks instead of a number. It means the indoor board does not detect the indoor fan motor turning at the commanded speed, so it treats it as stopped or faulty. The unit stops to protect the motor and prevent the indoor coil from freezing. The same number can mean something different on other brands.
Models covered: Fujitsu General (Fujitsu, O General) split and ducted units that show a two-digit error code on the wired remote or indoor display; older models show errors as lamp blink counts instead.
Symptoms4
- Little or no air from the indoor unit, then the unit stops.
- Rubbing or vibration noise from the indoor unit.
- On ducted units, airflow is weak at every outlet.
- The code returns minutes after a restart.
Possible causes5
- Dirt on the fan blades making it heavy or rub on the housing.
- A foreign object blocking the fan, or a filter fallen into the air path on ducted units.
- Worn motor bearings.
- A failed fan motor or rotation signal.
- A loose motor connector or a fault in its drive circuit on the board.
How to diagnose5
- Switch off at the breaker, then look into the air outlet with a torch for blockage or dirt.
- With power off, turn the fan gently; it should spin easily.
- The technician checks the motor connector and wires at the board.
- The technician measures motor supply and rotation signal against the manufacturer specification.
- The technician decides whether the motor or board is at fault before replacing parts.
How to fix5
- Remove the blockage and clean the filters with the power off.
- Have the fan and indoor coil fully cleaned.
- Replace the fan motor if its bearings are worn or it has failed.
- Reseat the connector or repair the wiring.
- Replace the indoor board if the motor circuit is faulty, then confirm the code does not return.
Repair cost
In Saudi riyals; the highlighted part is the expected range for this fault.
The cost is low for cleaning and clearing a blockage, and higher when the fan motor or indoor board must be replaced.
Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026
Frequently asked questions
Is cleaning sometimes enough?
Yes, especially if dust has built up on the fan. If the code returns after cleaning, the motor or board is the cause.
Should I keep using the unit?
No, keep it off until repaired. Running the compressor without enough airflow freezes the coil and can harm the compressor.
Was this explanation helpful?
Tap the stars to rate; you can change it later.
What was wrong? (optional)
This guide is for information only and does not replace an inspection by a qualified technician. If the fault involves brakes, steering, engine temperature, electrics or refrigerant, do not attempt the repair yourself.
Report a mistake
Spotted something inaccurate? Tell us and we will review and correct it.
Report received — thank you
This is your private tracking link. It shows the status and our reply as soon as it is posted.
The link is saved in this browser only.