Low Pressure Drop
What it means
This code appears on Daikin air conditioners, most often on SkyAir ducted and cassette units fitted with a low pressure sensor or switch, and means the suction-side refrigerant pressure fell below the allowed limit. The unit stops the compressor to protect it; the usual causes are low refrigerant or a closed service valve. The same code can mean something else on other brands.
Models covered: Daikin split air conditioners and Daikin ducted/cassette (SkyAir) units, which share the same error code system; the code shows on the wired remote or via the wireless remote check function.
Symptoms4
- The compressor stops and E4 appears.
- Weak or no cooling before the code appears.
- Frost on the suction pipe or outdoor service valves at times.
- The unit runs briefly after a restart and then trips.
Possible causes5
- Low refrigerant charge from a leak at the joints, piping or coils.
- An outdoor service valve left closed after installation or service.
- Poor airflow over the indoor evaporator from dirty filters or a weak fan.
- An electronic expansion valve fault or a restriction in the circuit.
- A faulty low pressure sensor or switch, or its wiring.
How to diagnose5
- Switch the unit off, clean the filters and confirm strong airflow from the indoor unit.
- If the unit was recently installed or serviced, have the technician confirm the service valves are fully open.
- The technician measures pressures and pipe temperatures and compares them with Daikin specifications.
- The technician searches for leaks with an electronic detector or soap solution on the joints.
- The technician checks the electronic expansion valve and the low pressure sensor and their wiring.
How to fix5
- Clean the filters and evaporator if poor airflow is the cause.
- Open the service valves fully if they are partly closed.
- A licensed technician repairs the leak, evacuates the system and recharges to the nameplate amount.
- Replace the electronic expansion valve or low pressure sensor if proven faulty.
- Run the unit, check pressures and cooling, and confirm the code does not return.
Repair cost
In Saudi riyals; the highlighted part is the expected range for this fault.
Opening a valve or cleaning filters is cheap, while a leak repair with recharge or a new expansion valve raises the cost.
Prices are rough estimates including the part and the technician’s fee, and vary with brand, model and part source.
Prices last updated: September 2026
Frequently asked questions
Does E4 always mean a refrigerant leak?
It is the most common cause, but a service valve left closed, blocked filters or a stuck expansion valve can do the same, so pressures should be measured before any recharge.
Does running with low refrigerant harm the compressor?
Yes. The compressor is cooled by returning refrigerant, and a low charge makes it run hot with poor lubrication, so avoid repeated restarts and call a licensed technician.
Was this explanation helpful?
Tap the stars to rate; you can change it later.
What was wrong? (optional)
This guide is for information only and does not replace an inspection by a qualified technician. If the fault involves brakes, steering, engine temperature, electrics or refrigerant, do not attempt the repair yourself.
Report a mistake
Spotted something inaccurate? Tell us and we will review and correct it.
Report received — thank you
This is your private tracking link. It shows the status and our reply as soon as it is posted.
The link is saved in this browser only.